I have created this climate:

- name: "Riscaldamento"
  unique_id: "termostato"
  modes:
    - "off"
    - "heat"
    - "cool"
  mode_command_topic: "home/riscaldamento_raffrescamento/TEST/mode/set"
  mode_state_topic: "home/riscaldamento_raffrescamento/TEST/mode/state"
  temperature_command_topic: "home/riscaldamento_raffrescamento/TEST/temp/set"
  current_temperature_topic: "home/riscaldamento_raffrescamento/TEST/temp/state"
  power_command_topic: "home/riscaldamento_raffrescamento/TEST/pump/set"
  payload_on: 1 
  payload_off: 0
  min_temp: 17
  max_temp: 28
  temp_step: 0.1
  precision: 0.1

thinking that the power_command_topic would be sent whenever the temperature would go over/under the one set, but nothing ever get send to that topic. How can I turn on the pump when the temperature goes under the one set and turn it off when it goes over?

  • paf@jlai.lu
    link
    fedilink
    English
    arrow-up
    2
    ·
    4 months ago

    here is my config yaml for climate. added hint for your case but i never had heat pump, does your heat pump only heat or does it also cool? exemple here is ok if only heat. If yours heat/cool, try some of the hacs thermostat addon. A quick search led me to this https://community.home-assistant.io/t/generic-thermostat-switch-between-heating-and-cooling/420053 which point to https://github.com/swingerman/ha-dual-smart-thermostat but i know they are more hacs addon for thermostat, you may need to search which is good for your use if the one above doesn’t suit your needs

    climate:
      - platform: generic_thermostat
        name: Thermostat Chambre (Riscaldamento)
        heater: switch.radiateur_chambre (device to toggle your heat pump)
        target_sensor: sensor.sonde_chambre_temperature (your temp sensor)
        min_temp: 12
        max_temp: 21
        ac_mode: false
        target_temp: 19
        cold_tolerance: 0
        hot_tolerance: 0.1
        min_cycle_duration:
          seconds: 300
        keep_alive:
          minutes: 3
        initial_hvac_mode: "off" (set this to heat if you want it to be active when HA start/reboot)
        away_temp: 12
        precision: 0.1
    
    • peregus@lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      24 days ago

      I completely missed your reply, sorry. My system cools and heats, and I really would like to avoid addons to avoid possible brakes in future updates. Do you think that it would be possible to do it with automation? (They can finally be divided into categories!)

        • peregus@lemmy.worldOP
          link
          fedilink
          English
          arrow-up
          1
          ·
          18 days ago

          Mmm…ok. Do you think that there is a way to hide one of them based on the season?

          • paf@jlai.lu
            link
            fedilink
            English
            arrow-up
            1
            ·
            18 days ago

            You can use an helper to toggle from one to another and use an automation to trigger it (or a simple switch on your dashboard).

            But if I were you, I would use a community add-on as dual AC isn’t a niche, I guess it will keep being updated in future. I’ve been using some community add-on for a couple of years and none have been dropped til now.